Deployment Guide – ExtremeXOS, NetSight, NAC on BlackDiamond X8, BlackDiamond 8K, Summit Switches
© Extreme Networks, Inc. All rights reserved. 4
Basic Bring-up
Console and Management Port
For the console port, the terminal or terminal emulator should have the settings 9600/8/N/1
(9600 baud, 8 data bits, 1 stop bit, no parity, ON/OFF flow control enabled).
By default the management port is in the “Mgmt” VLAN in the “VR-Mgmt” VR, and
administrators use it for management-related traffic, including IP connectivity to the switch,
syslog server, RADIUS server, NTP server, etc. You should configure the “Mgmt” VLAN with an
IP address and add a default route to the gateway.
1. Configure the IP address and subnet mask for the “Mgmt” VLAN. Then configure the default
gateway, specifying “VR-Mgmt” virtual router (VR).
Examples:
configure vlan Mgmt ipaddress 10.65.1.100 255.255.255.0
configure iproute add default 10.65.1.1 vr VR-Mgmt
2. Verify the management configuration using show commands:
Komentarze do niniejszej Instrukcji