System Health Check: Checksum Error
ExtremeWare Error Message Decoder 257
System Health Check: Checksum Error
Sys-health-check [EDP] checksum error (slow-path) on %s, port 0x%x %s",
slotName(rootSlot), portNum, serial_no);
Software Version
ExtremeWare 7.4, ExtremeWare 7.5
Hardware Version
All
Explanation
The message indicates that the switch has received an EDP packet with a wrong checksum. The log
displays the slot and port numbers on which the wrong EDP packet was received.
Action
1 Find the device that is transmitting the wrong EDP packet.
2 Run diagnostics to verify whether the hardware is in good condition.
3 Replace hardware if there is a problem.
4 If the problem appears again, contact Technical support.