Extreme Networks ExtremeWare Version 7.8 Dokumentacja Strona 923

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 978
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 922
EAPSD: State Transition to Complete, from Failed
ExtremeWare Error Message Decoder 923
EAPSD: State Transition to Complete, from Failed
EAPS: EAPSD eaps1a - State transition from Failed => Complete
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” and “e” series
Explanation
This message indicates that the EAPS master has moved to complete state from failed state. The EAPS
master moves to complete state when both the ring ports are up and it receives health check PDU on
the secondary port.
The EAPS master can be in any of the following states:
INIT
IDLE
FAILED
COMPLETE
Action
Informational only. No action needed.