DVMRP: Allocating Memory To Transmit Prune Failed
ExtremeWare Error Message Decoder 741
DVMRP: Allocating Memory To Transmit Prune Failed
DVMRP: Failed to alloc memory to Tx Prune ( <Src addr.> / <group addr.>)
Software Version
ExtremeWare 7.3
Hardware Version
All “i” series
Explanation
This message indicates that the switch failed to allocate buffer to transmit a prune message.
This message appears only if the
debug-trace is configured to dvmrp-message.
Action
1 Disable and Enable DVMRP; on the switch and on VLANs.
2 Check whether this error appears again.
If the error appears again, restart the switch.