Secondary Port Status Changed to Init
ExtremeWare Error Message Decoder 819
Secondary Port Status Changed to Init
<INFO:EAPS> eaps_runtime.c 2600: State Change, Failed => Init, EAPS="VLAN1"
Software Version
ExtremeWare 6.2.2 and later
Hardware Version
All
Explanation
This message indicates that the secondary ring-port came up on the master and caused it to transition
from Failed state to Init state. The secondary port is blocked immediately.
Action
Informational only. No action needed.