Extreme Networks ExtremeWare Version 7.8 Dokumentacja Strona 509

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 978
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 508
Invalid ESD Instance: Cannot Set Shared Port Timeout
ExtremeWare Error Message Decoder 509
Invalid ESD Instance: Cannot Set Shared Port Timeout
Could not set the shared-port-timeout. Invalid ESD instance %d
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” series
Explanation
This message indicates that the ESD (EAPS super domain) instance entered is not a valid ESD instance.
You can set the shared-port-timeout only if the ESD instance is valid.
Action
1 Check number of ESD instance exist in the system. You can create a maximum of 2 ESD instance on
a switch.
2 Delete the ESD instance that and create the ESD instance again.
Przeglądanie stron 508
1 2 ... 504 505 506 507 508 509 510 511 512 513 514 ... 977 978

Komentarze do niniejszej Instrukcji

Brak uwag