922 ExtremeWare Error Message Decoder
Informational Messages
EAPSD: State Transition to Init, from Failed
EAPS: EAPSD eaps1a - State transition from Failed => Init
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” and “e” series
Explanation
The message indicates that the EAPS master has moved to Init state from failed state. The EAPS master
moves to init state if both the ring ports are up, but the health check PDU is not received on the
secondary port.
The EAPS master can be in any of the following states:
INIT
IDLE
FAILED
COMPLETE
Action
Informational only. No action needed.