Przeglądanie stron 94
Packet Corruption on Motherboard
ExtremeWare Error Message Decoder 95
Packet Corruption on Motherboard
<CRIT:SYST> Sys-health-check [DIAG] pkt corruption on M-BRD
Software Version
ExtremeWare 7.2 and later
Hardware Version
All
Explanation
This message indicates that a CPU-Diagnostic packet corruption error was received on the Motherboard
of the switch. This switch is also a Summit stackable type.
Action
If the system reports more than three errors (any combination) within a 60 minute period, the system
needs attention. Given downtime availability, manual packet-memory diagnostics should be run,
followed by extended diagnostics.
run diagnostic packet-memory slot <slot #>
run diagnostic extended slot <slot #>