928 ExtremeWare Error Message Decoder
Informational Messages
EAPSD: Fail Timer Expiry Flag Cleared
EAPS: EAPSD eaps-up - Fail-timer-exp flag cleared
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” and “e” series
Explanation
This message indicates that the EAPS Master domain has cleared the fail timer flag. The message
appears when the EAPS ring link is restored and the EAPS master starts receives the health check PDU
on the secondary port.
The EAPS master domain set the fail timer expiry flag if the fail timer is expired, if the EAPS ring is
broken and the EAPS master domain is not able to receive the health check PDU.
Action
Informational only. No action needed.