Reached Maximum Limit of ESD Instance
ExtremeWare Error Message Decoder 753
Reached Maximum Limit of ESD Instance
Reached maximum limit of ESD instances.
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” series
Explanation
The message indicates that the switch has reached the maximum number of EAPS super domain (ESD)
instance. You can configure a maximum of two shared ports on a switch.
Action
1 Check the shared port configuration. You can create a maximum of two shared ports per switch.
2 If the error occurs with less than two shared ports, then reboot the switch.